Metal roofing
Architectural shingles
Tile roofing
GAF
Owens Corning
Flat & low-slopeFree roof inspection with deck photos before we talk money - GAF and Owens Corning certified installation
Why Long Beach Homeowners Choose CertainTeed Roofing
We provide Certainteed repair in Long Beach, from leak diagnosis and flashing repair to full CertainTeed roof replacements. As an independent provider, we are not affiliated with or authorized by CertainTeed, but our crews work on these roofs every week and know exactly how they fail in our coastal climate. What sets us apart is simple: a written price before any work starts, photo documentation of everything we find, and a 365-day warranty on every repair in writing. Call (562) 471-4832 and you’ll talk to a live person who can schedule your estimate.
Long Beach is a city with two very different roofing environments. Over in Naples and Belmont Shore, salt-laden air from the Pacific chews through metal flashing and fasteners within a few miles of the beach. Inland toward Bixby Knolls, UV exposure and heat do the real damage, baking asphalt shingles until they crack and curl. CertainTeed makes solid products, but no shingle is climate-proof. The key is knowing what to look for in each neighborhood.
Why Trust Crestview Roofing Co Long Beach for Your CertainTeed Roofing?
Our owner, Dylan Pace, grew up in Los Angeles and learned roofing fundamentals at Los Angeles Trade-Technical College before spending nearly two decades on roofs across Southern California. He has been working the Long Beach area for years, from tight bungalows in Belmont Shore to flat-topped commercial buildings near the Port. Dylan reads a roof the way a mechanic reads an engine. He climbs up, takes photos, and explains every line item on the estimate in plain language. “If I wouldn’t put it on my own roof, I’m not putting it on yours.”
That hands-on experience matters when you have a CertainTeed roof with a problem. We know the Landmark Pro line and its typical failure points. We know Presidential Shake TL and how its dimensional profile affects flashing at valleys. We know Matterhorn’s underlayment requirements. This is not generic roofing knowledge. It is brand-specific experience earned on actual Long Beach roofs. And everything we do is backed by The Relay Visibility Guarantee: a written price before any work begins, before-and-after photos, a live trackable arrival time, and a digital invoice sent by text.
Every Roof Repair includes the 365-Day Done Right Promise. If a covered repair fails within one year, we fix it at no charge, including a free second visit. No negotiation. No runaround. That guarantee is in writing on every single job.
Styles & brands we work with






Common CertainTeed Roofing Problems We Fix in Long Beach
CertainTeed shingles are well-made, but Long Beach’s coastal conditions expose weaknesses that generic roofing pages never mention. Here is what we actually find:
- Wind-lifted shingles along roof edges on Landmark Pro installations. The marine layer brings gusty onshore winds that catch shingle edges. When the original nailing was placed too high on the shingle, the wind lifts the tab and the nail loses its hold. We see this most often on east-facing roof slopes in Alamitos Heights and Naples, where morning marine winds hit hardest. The fix is re-nailing at the correct position and sealing the lifted tabs, not just slapping mastic on the edge.
- Granule loss and cracking on older asphalt shingles near the coast. Salt air is abrasive. Combined with intense afternoon sun on roofs more than a mile inland, it causes the asphalt to dry out and the ceramic granules to shed. You will see granules collecting in gutters or downspouts. On CertainTeed roofs from the mid-2000s and earlier, this often means the shingle is near the end of its service life. Patching helps short-term; replacement math becomes honest long-term advice.
- Flashing failures at valley intersections on Presidential Shake TL roofs. Presidential Shake TL is a thick, dimensional shingle with a deep profile. At valleys, the original step flashing sometimes was not extended long enough to account for the shingle’s height. Water runs under the flashing and into the decking. In Belmont Shore, we add salt corrosion to the mix. The metal flashing corrodes faster within a mile of the ocean, creating pinhole leaks that are hard to spot from the ground.
- Moisture wicking under the underlayment at eaves on Matterhorn roofs. Matterhorn is a solid architectural shingle, but it requires a proper underlayment system, including ice-and-water shield at the eaves in many installations. Some original installs omitted that membrane. Over time, moisture wicks up from the eave edge into the decking. By the time you see a ceiling stain, the decking may already be soft. We remove the affected shingles, replace rotted decking, and install proper membrane before re-shingling.
- Nail shiners from original installs using incorrect nailing patterns. A shiner is a nail driven so it sits in the exposed part of the shingle rather than the seal-down strip. When the sun heats the shingle, the nail head expands and contracts, letting water follow the nail shaft into the decking. We pulled back a ridge cap on a Landmark Pro roof in Alamitos Heights and found exactly this: the original installer nailed directly through the seal-down strip. We removed the damaged shingles, replaced two sheets of 1/2-inch CDX decking, and reinstalled the area with proper six-nail placement and new CertainTeed WinterGuard underlayment. The attic stayed dry through the next winter storm.
CertainTeed Parts & Our Repair-vs-Replace Approach
When you need a patch or a full replacement, matching materials matter. For CertainTeed shingles, we default to factory-spec shingles so the color and profile blend correctly. Landmark Pro has specific color lots, and we work with local suppliers to match as closely as possible. For Presidential Shake TL, we use the correct dimensional shingle rather than substituting a cheaper architectural line that will look wrong from the street.
For underlayment, flashing, and vent boots, we take a different approach. These are hidden components. We use quality aftermarket equivalents that meet or exceed CertainTeed’s published installation requirements. The performance is identical or better, and the cost is lower. That savings goes to you, not to a manufacturer’s brand markup. We stock common widths of step flashing, vent boots, and synthetic underlayment locally for fast turnaround on repairs.
The honest conversation happens when we find multiple failure points. If your CertainTeed roof has granule loss, cracked shingles, and corroded flashing all at once, patching each item separately will cost more per year of added life than a targeted replacement. We show you the math in writing. The decision is yours, but you will have real numbers to base it on. Call (562) 471-4832 for a free estimate with line-item pricing.
Our CertainTeed Service Process – Step by Step
- 1
Diagnosis with photos. We inspect the roof, take photos of every problem area, and document the findings. You see the same photos we see. For CertainTeed roofs, we check the specific failure points common to your model line: nailing patterns on Landmark Pro, valley flashing on Presidential Shake TL, underlayment condition on Matterhorn.
- 2
Written estimate with line items. Before any work starts, you get a written price. Every line item is spelled out: materials, labor, decking replacement if needed, disposal. The number on the page is the number on the invoice.
- 3
Repair or replacement. Our techs arrive in uniform with a live trackable arrival time. For repairs, we use OEM-spec CertainTeed shingles where visible and quality aftermarket underlayment and flashing where hidden. For replacements, we follow CertainTeed’s published installation specs, including proper nailing patterns and underlayment requirements.
- 4
Testing and documentation. We water-test repairs where practical and photograph the finished work. You get before-and-after photos and a digital invoice sent by text.
- 5
365-day warranty in writing. Every repair is covered by the 365-Day Done Right Promise. If it fails within a year, we return at no charge and make it right.
See the difference
Before
After
Before
After
Before
AfterCertainTeed Products We Service & Install in Long Beach
Our crews work on the full range of CertainTeed residential roofing products, including Certainteed in Garden Grove and surrounding areas. We regularly service and install Landmark Pro, the workhorse architectural shingle found across Long Beach neighborhoods. We also handle Presidential Shake TL, a high-profile dimensional shingle that requires careful flashing work. Northgate ClimateFlex, designed for impact and wind resistance, is an option we quote for coastal and fire-zone areas. Matterhorn architectural shingles appear on many mid-century and newer builds, and we are familiar with their underlayment requirements. We stock common repair materials locally and order full replacement shingles with a typical lead time of three to five business days. For an accurate quote on your CertainTeed product line, call (562) 471-4832.
We Also Service These Brands
While this page focuses on CertainTeed, Crestview Roofing Co Long Beach is a multi-brand roofing company. We install and repair GAF and Owens Corning shingles regularly, plus IKO, Atlas, Tamko, and Boral. If you are comparing brands or not sure what is on your roof, we can identify the product and quote accordingly.
FAQs – CertainTeed Roofing Service in Long Beach
Color matching on existing roofs is never perfect, but we get close. Landmark Pro colors shift with sun exposure and age. A new bundle of the same color will look brighter than shingles that have been on the roof for five years. We work with local suppliers to find the closest current lot, and we tell you honestly what the patch will look like before we start. Sometimes the better solution is re-roofing an entire plane rather than patching a visible area. Call (562) 471-4832 and we will assess your roof in person.
Yes, we install Northgate ClimateFlex. The shingle carries a Class 4 impact rating and enhanced wind resistance, which makes sense for coastal Long Beach homes exposed to salt air and gusty marine-layer winds. The extra cost over Landmark Pro typically runs 15 to 25 percent, depending on the roof size and complexity. For a bungalow in Belmont Shore or a larger home in Bixby Knolls, the upgrade can pay off in reduced wind-lift issues over time. We can quote both options side by side so you see the real dollar difference.
Almost always an installation issue. When shingles lift at the edges, it means the original nails were placed too high on the shingle or the seal-down strip was never properly engaged. CertainTeed’s installation specs require nails in a specific zone, and when that is missed, wind gets under the tabs. A manufacturing defect is possible but rare. We can inspect the nailing pattern and tell you which one you are dealing with. The repair is straightforward: re-nail correctly and reseal. Call (562) 471-4832 for an inspection.
Underlayment can absolutely fail before the shingles do, especially near the coast. Synthetic underlayment rated for 30 to 50 years should outlast most shingles, but older felt underlayment from the 2000s degrades faster, particularly in Long Beach’s humid marine layer. Near the eaves, where moisture accumulates and salt air is concentrated, we see underlayment failure in 15 to 20 years. If your shingles look fine but you have a leak, do not assume the shingles are the problem. The underlayment is often the culprit, and we can repair the affected section without replacing the whole roof.
No. We are an independent roofing company and are not affiliated with or authorized by CertainTeed. We do not perform manufacturer warranty service. However, we follow CertainTeed’s published installation specifications on every job, which matters if you ever need to file a manufacturer warranty claim. Our own workmanship warranty, the 365-Day Done Right Promise, covers every repair we make for a full year in writing. You get two layers of protection: your manufacturer shingle warranty and our repair guarantee.
Repair work on CertainTeed roofs in Long Beach typically runs from $425 to $1,800, depending on the issue. A simple flashing repair near a chimney or vent runs $425 to $750. A shingle patch with decking replacement runs $800 to $1,400. Full replacement of a Landmark Pro roof on a typical Long Beach bungalow runs $9,500 to $16,000, depending on roof size, slope, decking condition, and whether we need to address underlayment or flashing. Every estimate is written, line-itemed, and delivered before any work starts. For an exact number on your roof, call (562) 471-4832. Estimates are free.
Book Your CertainTeed Service in Long Beach, CA
We keep this simple. Call (562) 471-4832 and a live person picks up. Tell us what is happening with your CertainTeed roof, and we will schedule a free estimate with a written price before any work begins. No four-hour windows. No voicemail loops. Just a straight answer and a fair number.
Written by Dylan Pace, Owner at Crestview Roofing Co Long Beach, serving Long Beach since 2000.